Search product by keywords
Search product by code
test

SMARTY7

Electromechanical actuator BRUSHLESS, low voltage, super intensive use. Irreversible. For swing gates with gate leaf up to 7 m.

Brushless
Intensive use
Digital Encoder
Industrial sector
Commercial sector
Power line supply:    230V AC - 50Hz
Motor power supply:    36V
Power rating:    200W
Frequency of use:    Intensive use
Thrust:    600 - 7000N
Operating temperature:    -20 C° +55 C°
Protection level:    IP44
Reductor Type:    Irreversible
Manoeuvre speed:    1,6 cm/s
Opening time:    35-50 s
Stroke:    520 mm
Limit switch:    Mechanical stopper in opening and closing
Recommended digital controllers:    230V: EDGE1/BOX - 115V: EDGE1/BOX/115
Encoder:    Digital native encoder SENSORLESS 48 PPR
Operating cycles per day (opening/closing - 24 hours no stop):    1000
Maximum dimension product in mm (L x W x H):    1312 x 116 x 165
Product weight packed (Kg):    17,1
Number items per pallet/box:    36
Dimensions
Predisposition for standard installation
MC782
Kit 2 mechanical stop SMARTY series.
KT238
Kit 3 hinge plates long series, to weld, for series SMARTY7 - SMARTY7R.
R99/C/001
Signboard "Automatic Opening".
RL669
Kit for release from outside without handle for series SMARTY.

Download
technical manual
RL670
European cylinder key for release system series SMARTY - BIONIK.

Download
technical manual
RL671
Metallic wire length 3 m for release from outside.
SMARTY/EMA
Module Encoder Magnetic Absolute for SMARTY Series.

Download
technical manual
B74/BCONNECT vers. HW2
Module WI-FI B-CONNECT - Remote management and programming system in IP web browser mode via Wi-Fi hot spot P2P connection for Brushless control units (B70/2ML - EDGE1 - CTRL - B70/1DC - B70/1DCHP - B70/1T - B70/1THP - F70/IPU36).

Download
technical manual
R99/C/001AL
Signboard "Automatic Opening" Aluminium version.
B71/PBX36/BOX/115
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 115V AC.

Download
technical manual
B71/PBX36/BOX
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 230V AC.

Download
technical manual
B71/PBX/BOX
Hybrid inverter, “Full Solar” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels for powering the brushless digital controllers.

Download
technical manual

Size in Cm: Lenght: 134 - Widht.: 13 - Heigth: 16


Download
technical manual