TW110/1600/HS/115
Electromechanical HIGH SPEED BRUSHLESS motor, low voltage, super intensive use, with SENSORED digital magnetic encoder at 4096 PPR, irreversible ideal for sliding gates up to 1600 kg, with digital controller in pre-wired plastic box series B70.
New
Brushless
Intensive use
High Speed
4096 PPR Digital Magnetic Encoder
Industrial sector
condominium
1600 kg | |
115V AC - 60Hz | |
36V | |
240W | |
Intensive use | |
380N | |
-20+55°C | |
IP44 | |
Irreversible | |
21 m/min (0.35 m/s) | |
Without limit switches - optional | |
B70/1THP | |
Digital magnetic encoder SENSORED, 4096 PPR | |
Optional 2 external battery 12V 4,5AH | |
Z17/mod 4 | |
150000 | |
185 x 160 x 333 | |
17,4 | |
30 |
Dimensions
Dimensions
Predisposition for standard installation
GA550
Galvanised steel rack 22x22x1000 module 4.
Galvanised steel rack 22x22x1000 module 4.
GA551
Galvanised steel rack 30x12x1000 module 4 with spacers and screws.
Galvanised steel rack 30x12x1000 module 4 with spacers and screws.
GA554
Pocket of 6 spacers (2,5 cm) and screws.
Pocket of 6 spacers (2,5 cm) and screws.
R99/C/001
Signboard "Automatic Opening".
Signboard "Automatic Opening".
B71/BCHP/EXT
Kit for emergency batteries charger for Brushless digital controller EDGE1/BOX - B70/1DCHP - B70/1THP 36V DC with plug-in card, with 2 recovery batteries 12V DC, 4.5 Ah. Box case included.
Kit for emergency batteries charger for Brushless digital controller EDGE1/BOX - B70/1DCHP - B70/1THP 36V DC with plug-in card, with 2 recovery batteries 12V DC, 4.5 Ah. Box case included.
B71/BCHP/BOX
Kit for emergency batteries charger for Brushless digital controller EDGE1/BOX - B70/1DCHP - B70/1THP 36V DC. Box case included and without recovery batteries.
Kit for emergency batteries charger for Brushless digital controller EDGE1/BOX - B70/1DCHP - B70/1THP 36V DC. Box case included and without recovery batteries.
RL671
Metallic wire length 3 m for release from outside.
Metallic wire length 3 m for release from outside.
LT328
Pinion Z17 mod. 4 with increased thickness H.38 for series R30 - G30 - TW110 - E30 (except BG30/804/HS - BG30/1504/HS - TW110/1000/HS).
Pinion Z17 mod. 4 with increased thickness H.38 for series R30 - G30 - TW110 - E30 (except BG30/804/HS - BG30/1504/HS - TW110/1000/HS).
LT331
Pinion Z11 mod. 6 only for series G30 - BG30 - TW110 (except BG30/804/HS - BG30/1504/HS - TW110/1000/HS).
Pinion Z11 mod. 6 only for series G30 - BG30 - TW110 (except BG30/804/HS - BG30/1504/HS - TW110/1000/HS).
B74/BCONNECT vers. HW2
Module WI-FI B-CONNECT - Remote management and programming system in IP web browser mode via Wi-Fi hot spot P2P connection for Brushless control units (B70/2ML - EDGE1 - CTRL - B70/1DC - B70/1DCHP - B70/1T - B70/1THP - F70/IPU36).
Module WI-FI B-CONNECT - Remote management and programming system in IP web browser mode via Wi-Fi hot spot P2P connection for Brushless control units (B70/2ML - EDGE1 - CTRL - B70/1DC - B70/1DCHP - B70/1T - B70/1THP - F70/IPU36).
R99/C/001AL
Signboard "Automatic Opening" Aluminium version.
Signboard "Automatic Opening" Aluminium version.
B71/PBX36/BOX/115
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 115V AC.
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 115V AC.
B71/PBX36/BOX
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 230V AC.
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 230V AC.
B71/PBX/BOX
Hybrid inverter, “Full Solar” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels for powering the brushless digital controllers.
Hybrid inverter, “Full Solar” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels for powering the brushless digital controllers.
MC783
Pair of increased magnets for magnetic limit switch, only for GA558.
Pair of increased magnets for magnetic limit switch, only for GA558.
Size in cm: Lenght: 35 - Widht: 22 - Heigth: 38