Search product by keywords
Search product by code
test

BI/004HP/IS/115

Automatic Barrier BRUSHLESS 36V DC super intensive use up to 4 meters, with operator and and built-in digital control panel and absolute encoder on board. Version with housing unit made in brushed stainless steel AISI 304.

Brushless
Intensive use
Digital Encoder
Residential sector
Industrial sector
Commercial sector
Barriers:    Up to 4 mt long
Power line supply:    115V AC - 60Hz
Motor power supply:    36V DC
Electrical absorption:    max 15A
Power rating:    220W
Frequency of use:    Super intensive use
Torque:    10 - 200 N m
Operating temperature:    - 20 + 55 C°
Protection level:    IP54
Reductor Type:    Irreversible
Opening time:    3 ÷ 6 (sec)
Onboard control unit:    CTRL Digital Controller 36V DC
Encoder:    Digital native encoder + magnetic digital SENSORED, 4096 PPR
Accessories power supply:    24V DC
Colour:    Cabinet: brushed stainless steel AISI 304 - Head: black arabesque silver painted - Boom support: black arabesque silver painted - Boom: painted RAL9010 matt
Release system:    European Key cylinder
Batteries recovery:    Available (optional)
BUS synchronization Master/Slave:    Yes
Operating cycles per day (opening/closing - 24 hours no stop):    5000 cycles
Maximum dimension product in mm (L x W x H):    380 x 270 x 1237
Product weight packed (Kg):    73,7
Number items per pallet/box:    6
Dimensions
KT230/IS
Fixing plate, inox AISI 304 version, with stay bolts and screws for BI/001PE - BI/001PC - BI/004HP - BI/006.

Download
technical manual
SP/72/01
Spring diameter 72 mm for barriers.

Download
technical manual
SP/83/01
Spring diameter 83 mm for barriers.

Download
technical manual
KT231
Fixing plate for code BAFS/01, BAFS/02, BAFS/03, BAFS/04, BAFS/05.

Download
technical manual
BAFS/01
Fixed support for bars.

Download
technical manual
BAFS/03
Fixing support with bolt predisposition for bars.

Download
technical manual
BAFS/02
Fixing support, adjustable.

Download
technical manual
BAFS/04
Fixing support adjustable, with bolt predisposition for bars.

Download
technical manual
BAMS/01
Mobile support for bars.

Download
technical manual
BARK/02
Barrier skirting in aluminum, with stainless steel screws mounted on bronze bushings. Single module of length 2 meters.

Download
technical manual
BT12V45
Battery 12V 4.5 Ah (1 pc).
DLD1/24
Loop detector for 1 loop, 2 output, 24V AC/DC.

Download
technical manual
DLD2/24
Loop detector for 2 loop, 2 output + output alarm, 24V AC/DC.

Download
technical manual
ALED/4C
4-metre LED strip with connection cable for barrier boom (red colour).

Download
technical manual
BI/BAT/KIT
Kit for emergency batteries charger for brushless digital controller CTRL 36V DC with plug-in card, with 2 recovery batteries 12V DC, 4.5 Ah. Kit for BIONIK barrier.

Download
technical manual
BI/BCHP
Plug-in card, batteries charger, for brushless digital controller CTRL 36V DC, without recovery batteries, for BIONIK barrier.

Download
technical manual
BAMS/01/EXT
Extension 20cm for mobile support BAMS/01.

Download
technical manual
BAFS/05
Adjustable fixed support with vandal-proof magnetic suction cup complete with B72/DGS demagnetizer card.

Download
technical manual
B73/EXP
Signal status board, 2 output for CTRL - CTRL/P

Download
technical manual
CRA/BAR
Post for photocells G90/F2ES - G90/F4ES - for spaced installation on a barrier cabinet (+23cm).
ACS/BA/60
Break-away system for barrier, compatible only with BA/60/3 boom arm.

Download
technical manual
R99/BASB20
Pack of 20 stickers for barrier.
B74/BCONNECT vers. HW2
Module WI-FI B-CONNECT - Remote management and programming system in IP web browser mode via Wi-Fi hot spot P2P connection for Brushless control units (B70/2ML - EDGE1 - CTRL - B70/1DC - B70/1DCHP - B70/1T - B70/1THP - F70/IPU36).

Download
technical manual
B71/PBX36/BOX/115
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 115V AC.

Download
technical manual
B71/PBX36/BOX
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 230V AC.

Download
technical manual
B71/PBX/BOX
Hybrid inverter, “Full Solar” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels for powering the brushless digital controllers.

Download
technical manual
ACS/BA/68
Break-away system for barrier, compatible with BA/68/3 and BA/68/4 boom arm.

Download
technical manual
B73/LTM
RGB boom light and traffic light control device for CTRL.

Download
technical manual
ALED/4C/RGB
4-metre multicoloured RGB LED (red, green + other colours) strip with connection cable for barrier boom.

Download
technical manual
BI/BLED/6/RGB
Multicoloured RGB LED strip (red, green + other colours) with connection cable for BI/004HP - BI/006 barrier header.

Download
technical manual
CRA/BAR/M90
Post for photocells M90/F2ESO - M90/F4ESO for spaced installation on a barrier cabinet (+23 cm).
BA/91/3
White painted aluminum rod, 3 meters long, with LED cover profile and impact resisteng rubber profile.

Download
technical manual
BA/91/4
White painted aluminum rod, 4 meters long, with LED cover profile and impact resisteng rubber profile.

Download
technical manual
JNT/BA/91
Internal boom bar joint in anodized aluminum including fixing screws for bars BA/91.

Download
technical manual
SND/BA/91/DW
Articulated joint 90° with lower tie rod for boom arms BA/91.

Download
technical manual
SND/BA/91/UP
Articulated joint 90° with upper tie rod for boom arms BA/91.

Download
technical manual

Size in Cm: Lenght: 122 - Widht.: 42 - Heigth: 30