Search product by keywords
Search product by code
test

BI/004HP/115

Automatic Barrier BRUSHLESS 36V DC super intensive use up to 4 meters, with operator and and built in digital control panel and absolute encoder on board.

Brushless
Intensive use
Digital Encoder
Residential sector
Industrial sector
Commercial sector
Barriers:    Up to 4 mt long
Power line supply:    115V AC - 60Hz
Motor power supply:    36V DC
Electrical absorption:    max 15A
Power rating:    220W
Frequency of use:    Super intensive use
Torque:    10 - 200 N m
Operating temperature:    - 20 + 55 C°
Protection level:    IP54
Reductor Type:    Irreversible
Opening time:    3 ÷ 6 (sec)
Onboard control unit:    CTRL Digital Controller 36V DC
Encoder:    Digital native encoder + magnetic digital SENSORED, 4096 PPR
Accessories power supply:    24V DC
Colour:    Cabinet: painted RAL9006 arabesque grey - Head: black arabesque silver painted - Boom support: black arabesque silver painted - Boom: painted RAL9010 matt
Release system:    European Key cylinder
Batteries recovery:    Available (optional)
BUS synchronization Master/Slave:    Yes
Operating cycles per day (opening/closing - 24 hours no stop):    5000 cycles
Maximum dimension product in mm (L x W x H):    380 x 270 x 1237
Product weight packed (Kg):    74,7
Number items per pallet/box:    6
Dimensions
KT230
Fixing plate with stay bolts and screws for BI/001PE - BI/001PC - BI/004HP - BI/006.

Download
technical manual
SP/72/01
Spring diameter 72 mm for barriers.

Download
technical manual
SP/83/01
Spring diameter 83 mm for barriers.

Download
technical manual
KT231
Fixing plate for code BAFS/01, BAFS/02, BAFS/03, BAFS/04, BAFS/05.

Download
technical manual
BAFS/01
Fixed support for bars.

Download
technical manual
BAFS/03
Fixing support with bolt predisposition for bars.

Download
technical manual
BAFS/02
Fixing support, adjustable.

Download
technical manual
BAFS/04
Fixing support adjustable, with bolt predisposition for bars.

Download
technical manual
BAMS/01
Mobile support for bars.

Download
technical manual
BARK/02
Barrier skirting in aluminum, with stainless steel screws mounted on bronze bushings. Single module of length 2 meters.

Download
technical manual
BT12V45
Battery 12V 4.5 Ah (1 pc).
DLD1/24
Loop detector for 1 loop, 2 output, 24V AC/DC.

Download
technical manual
DLD2/24
Loop detector for 2 loop, 2 output + output alarm, 24V AC/DC.

Download
technical manual
ALED/4C
4-metre LED strip with connection cable for barrier boom (red colour).

Download
technical manual
BI/BAT/KIT
Kit for emergency batteries charger for brushless digital controller CTRL 36V DC with plug-in card, with 2 recovery batteries 12V DC, 4.5 Ah. Kit for BIONIK barrier.

Download
technical manual
BI/BCHP
Plug-in card, batteries charger, for brushless digital controller CTRL 36V DC, without recovery batteries, for BIONIK barrier.

Download
technical manual
KT239
Kit DIN rail with magnetic support.

Download
technical manual
BAMS/01/EXT
Extension 20cm for mobile support BAMS/01.

Download
technical manual
BAFS/05
Adjustable fixed support with vandal-proof magnetic suction cup complete with B72/DGS demagnetizer card.

Download
technical manual
B73/EXP
Signal status board, 2 output for CTRL - CTRL/P

Download
technical manual
KT242
Cable passage kit with magnetic support for barriers.

Download
technical manual
CRA/BAR
Post for photocells G90/F2ES - G90/F4ES - for spaced installation on a barrier cabinet (+23cm).
ACS/BA/60
Break-away system for barrier, compatible only with BA/60/3 boom arm.

Download
technical manual
R99/BASB20
Pack of 20 stickers for barrier.
B74/BCONNECT vers. HW2
Module WI-FI B-CONNECT - Remote management and programming system in IP web browser mode via Wi-Fi hot spot P2P connection for Brushless control units (B70/2ML - EDGE1 - CTRL - B70/1DC - B70/1DCHP - B70/1T - B70/1THP - F70/IPU36).

Download
technical manual
B71/PBX36/BOX/115
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 115V AC.

Download
technical manual
B71/PBX36/BOX
Hybrid inverter, “Network Assisted” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels or mains supply for powering the 36V DC brushless digital controllers with a mains voltage of 230V AC.

Download
technical manual
B71/PBX/BOX
Hybrid inverter, “Full Solar” version, for powering the automation. Also provides a battery-charger function thanks to the connection to the solar panels for powering the brushless digital controllers.

Download
technical manual
ACS/BA/68
Break-away system for barrier, compatible with BA/68/3 and BA/68/4 boom arm.

Download
technical manual
B73/LTM
RGB boom light and traffic light control device for CTRL.

Download
technical manual
ALED/4C/RGB
4-metre multicoloured RGB LED (red, green + other colours) strip with connection cable for barrier boom.

Download
technical manual
BI/BLED/6/RGB
Multicoloured RGB LED strip (red, green + other colours) with connection cable for BI/004HP - BI/006 barrier header.

Download
technical manual
CRA/BAR/M90
Post for photocells M90/F2ESO - M90/F4ESO for spaced installation on a barrier cabinet (+23 cm).
BA/91/3
White painted aluminum rod, 3 meters long, with LED cover profile and impact resisteng rubber profile.

Download
technical manual
BA/91/4
White painted aluminum rod, 4 meters long, with LED cover profile and impact resisteng rubber profile.

Download
technical manual
JNT/BA/91
Internal boom bar joint in anodized aluminum including fixing screws for bars BA/91.

Download
technical manual
SND/BA/91/DW
Articulated joint 90° with lower tie rod for boom arms BA/91.

Download
technical manual
SND/BA/91/UP
Articulated joint 90° with upper tie rod for boom arms BA/91.

Download
technical manual

Size in Cm: Lenght: 122 - Widht.: 42 - Heigth: 30